Water Heaters

Sediment buildup
Water heaters heating of water causes calcium carbonate to
precipitate out and settle to the bottom of the tank. Steam bubbles form under
the sediment when the burners come on causing popping and other noises.
Regular flushing helps prevent sediment build up.
Not producing enough hot water
Check for a broken dip tube, wrong setting on a thermostat,
a defective thermostat, burned out heating elements (electric), or a heavy build
up of sediment.
Dip tube
The dip tube is a long slender tube that fits down into the
water heaters inlet, and usually has a small hole about 6 inches from the top.
The dip tube directs the incoming cold liquid down to the bottom of the tank.
If the dip tube is broken, the incoming cold liquid can mix with the out going
hot liquid and cause it to seem as though you are running out.
Noisy tank
Noise coming from gas models can often be caused by the sediment
build up in the bottom of the tank. Steam bubbles form under the sediment. The
thumping and popping noises are created by the bubbles escaping from under the
sediment.
Sizzling noises can be caused by condensation dripping onto the
hot burner.
Thermal expansion
When water is heated it expands. If the inlet is not blocked by
a check valve, pressure reducing valve, or other device, the increase in volume
simply travels back into the source. If the inlet is blocked, this increase in
volume will cause an increase in pressure, sometimes to dangerous levels.
The T&P (Temperature-pressure) valve relieves this pressure by
discharging some liquid. A thermal expansion tank can be installed in the line
that will absorb the increase in volume, preventing the relief valve from
discharging unnecessarily.
T&P valves are strictly an emergency measure and should be
replaced every 2 years. At 180 psi , the temperature that the T&P valve opens,
damage can occur to your system and you may have voided the warranty on your
water heater.
The improper installation of backflow preventers can block the
thermal expansion leading to operation of the T&P Valve.
Water Hammer
When liquid is traveling in the pipes it has kinetic energy
(energy of motion). When a valve shuts off suddenly a shock wave results.
Hammer most often occurs when a valve shuts off suddenly.
Commercial arrestors are available to combat this problem. They consist of a
small air bladder within a cylinder plumbed to the piping system near the valve
causing the problem. Some hardware stores carry them.
Sometimes if the piping is sagging then supporting the pipe
solves the problem.
Milky color
Water contains dissolved oxygen and other gases. When it's
heated it has less ability to hold these gases and when the pressure is lowered
as the liquid comes out of the tap these gasses can form tiny bubbles giving
the liquid a milky appearance. Letting it stand for a few minutes will allow
these bubbles to rise out of the liquid and it resumes its clear appearance.
If you life in an earthquake prone area then be sure to strap
the tank to the wall to prevent damage and possible injury during an earthquake.